日本光明理化工业株式会社从1947年开始,在气体分析领域开拓了六十余年 , 形成了驰名于世的 ” 北川 ” 式气体检测管。气体快速分析法 ” 北川 ” 的历史就是日本检测管的历史 。目前是世界上*大的检测管生产厂家,也是日本**家通过美国SEI的认证,欧盟的认证的检测管厂家。公司不仅有ISO9001:2000的认证,还获得了环境管理的ISO14001的认证。北川式手动气体采集器AP-20 备有采气完成指示计 , 可以清楚的判明采气是否完成 . • 有专门截留玻璃的截留槽 , 以防止检测管割尖时玻璃片飞溅 . • 有采气容积为 50 毫升和 100 毫升的两段式制动卡 . • 采气器极为小巧 , 并有便于携带的皮具包 。
Tube No.132SB
1. PERFORMANCE
1) Measuring range :5-500 ppm
Number of pump strokes 1(100ml)
2) Sampling time :1.5 minutes/1 pump stroke
3) Detectable limit :2 ppm
4) Shelf life :1.5 years(Necessary to store in a refrigerated place ; 0~10℃)
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change :White→Reddish orange
2. RELATIVE STANDARD DEVIATION
RSD-low:15% RSD-mid.:10% RSD-high:10%
3. CHEMICAL REACTION
By decomposing with an Oxidizer, Chlorine is produced. This Chlorine reacts with o-Toluidine and red
Orthoquinone is produced.
CH2=CHCI+PbO2→CI2
4. CALIBRATION OF THE TUBE
GAS CHROMATOGRAPHY
5. INTERFERENCE AND CROSS SENSITIVITY
GAS To pump
PRETREAT TUBE DETECTOR TUBE
500
400
300
200
100
50
20
10
5
ppm
(Gray)
132SB VINYL CHLORIDE
Substance Interference ppm Coexistence
Hydrogen chloride Similar stain is produced. Higher readings are given.
Chlorine 〃〃
Ohytdhreorc haarbloognesns or Halogenated 〃〃
TEMPERATURE CORRECTION TABLE
Scale True Concentration (ppm)
Readings 0℃ 5℃ 10℃ 15℃ 20℃ 30℃ 40℃
(ppm) (32°F) (41°F) (50°F) (59°F) (68°F) (86°F) (104°F)
500 - - 820 600 500 430 400
400 - 850 610 470 400 340 310
300 - 640 440 350 300 250 230
200 750 400 300 230 200 160 140
100 340 200 150 120 100 80 70
50 150 100 70 60 50 40 30
20 50 40 30 25 20 15 10
10 25 20 15 10 10 10 5
5 15 10 10 5 5 5 5
NH2+CI2
CH3 CH3
H2N CIN=? =? =?NCI
CH3 CH3
1. PERFORMANCE
1) Measuring range :5-500 ppm
Number of pump strokes 1(100ml)
2) Sampling time :1.5 minutes/1 pump stroke
3) Detectable limit :2 ppm
4) Shelf life :1.5 years(Necessary to store in a refrigerated place ; 0~10℃)
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change :White→Reddish orange
2. RELATIVE STANDARD DEVIATION
RSD-low:15% RSD-mid.:10% RSD-high:10%
3. CHEMICAL REACTION
By decomposing with an Oxidizer, Chlorine is produced. This Chlorine reacts with o-Toluidine and red
Orthoquinone is produced.
CH2=CHCI+PbO2→CI2
4. CALIBRATION OF THE TUBE
GAS CHROMATOGRAPHY
5. INTERFERENCE AND CROSS SENSITIVITY
GAS To pump
PRETREAT TUBE DETECTOR TUBE
500
400
300
200
100
50
20
10
5
ppm
(Gray)
132SB VINYL CHLORIDE
Substance Interference ppm Coexistence
Hydrogen chloride Similar stain is produced. Higher readings are given.
Chlorine 〃〃
Ohytdhreorc haarbloognesns or Halogenated 〃〃
TEMPERATURE CORRECTION TABLE
Scale True Concentration (ppm)
Readings 0℃ 5℃ 10℃ 15℃ 20℃ 30℃ 40℃
(ppm) (32°F) (41°F) (50°F) (59°F) (68°F) (86°F) (104°F)
500 - - 820 600 500 430 400
400 - 850 610 470 400 340 310
300 - 640 440 350 300 250 230
200 750 400 300 230 200 160 140
100 340 200 150 120 100 80 70
50 150 100 70 60 50 40 30
20 50 40 30 25 20 15 10
10 25 20 15 10 10 10 5
5 15 10 10 5 5 5 5
NH2+CI2
CH3 CH3
H2N CIN=? =? =?NCI
CH3 CH3